 Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Applications
s
Designed for a variety of applications: -- S Series: single channel -- V Series: video Booster/power amplifier Line amplifier Preamplifier
s s s
Description
The 1724-Type Erbium-Doped Fiber Amplifier (EDFA) has been designed for use in a variety of applications and is available in application-specific versions:
s
Designed for use in single-channel or video applications, the standard 1724-Type EDFA incorporates a DB-25 connector and a microcontroller with TTL compatible alarm monitoring.
S Series for single-channel, preamplifier applications (see Table 4, page 6, for performance specifications) -- High gain -- Low noise figure V Series for video, analog, or booster applications (see Table 5, page 6, for performance specifications) -- Supports a wide range of output powers -- Low noise figure -- Low power dissipation -- Adjustable output power
Features
s s s s s s s s s s s
s
High saturation output power, >22 dBm Low power consumption, <12 W @ 45 C Low noise Single 5 V operation Wide input signal bandwidth Wide operating temperature range, 0 C to 65 C Optical input and output taps Isolated input and output Programmable input and output Connectorized single-mode fiber pigtail Standard serial communication channels
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Data Sheet July 1999
and fiber outputs (using SC/PC optical connectors) at 180 degrees relative to a DB25 electrical connector. The standard product does not include a heat sink.
Description (continued)
The versatile 1724-Type EDFA operates over a wide temperature range, exhibits extremely low power dissipation, and offers a variety of alarms and monitors. Optimum performance and system stability are supported through the use of optical isolation at the input and output. Optical input and output are through singlemode fiber pigtails terminated with optical connectors. The EDFA incorporates optical input and output taps that are monitored via an integral microcontroller. Significant performance benefits are achieved with the microcontroller, which stabilizes the temperature of the pumps and maintains constant optical output power. Contact your Agere Systems Inc. Account Manager to discuss electrical or optical connector options not listed in the Ordering Information section.
TTL-Compatible Alarm Outputs
Loss of Input Power Alarm
If the input power is more than 2 dBm below the minimum PIN, the loss of input power alarm (pin 19) will activate (TTL-logic 1).
Loss of Output Power Alarm
If the output power decreases by more than 2 dB from its beginning-of-life value, the loss of output power alarm (pin 8) will activate (TTL-logic 1).
Standard Features
The standard 1724-Type EDFA incorporates the optical architecture illustrated in Figure 1. The standard features include:
s
Pumps Temperature Alarm
If the laser temperature for the pump(s) exceeds 35 C, the pump temperature alarm (pin 10) will activate (TTLlogic 1).
Exceptional performance benefits with the integral microcontroller, which precisely controls the output power and allows for changes to power settings as necessary. Single 5 V power supply eliminates the need for dual voltage source circuits. DB-25 electrical connector allows for easy electrical connectivity. Optical input tap enables input monitoring and control. Optical output tap enables precise output monitoring and control and, when used in conjunction with the microcontroller, typically provides 0.2 dB of output power stability over temperature and wavelength. SC/PC optical connector Low power dissipation Alarms: -- Loss of input power alarm -- Loss of output power alarm -- Pump bias alarm (>95% of EOL value) -- Pump temperature alarm (TL > 35 C) -- EDFA temperature alarm (TC > 60 C) Advanced microprocessor design requires minimal engineering for a shelf-level product. Standard mechanical outline includes metric screws
Pumps Bias Alarm
If the bias current for the pump(s) exceeds 95% of its EOL value, the pump bias alarm (pin 9) will activate (TTL-logic 1).
s
s
s
EDFA Temperature Alarm
If the case temperature exceeds 60 C, then the EDFA temperature alarm (pin 7) will activate (TTLlogic 1).
s
s s s
Optional Features
Other feature and package options for the 1724-Type EDFA include:
s s
Alternative optical connectors Integral heat sink
s
s
2
Agere Systems Inc.
Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Block Diagram
OPTICAL INPUT SIGNAL
INPUT TAP
OPTICAL GAIN
OUTPUT TAP
OPTICAL OUTPUT SIGNAL
PD #1 INPUT POWER MONITOR
PD #2 OUTPUT POWER MONITOR
MICROCONTROLLER
1-904 (C)
Figure 1. 1724-Type EDFA Block Diagram
Pin Information
Table 1. Pin Descriptions for a Microcontrolled (Full) Amplifier
Pin 1 2 3 4 5 6 7 8 9 10 11 12 13
1. 2. 3. 4. 5.
Description 5.0 V (0.25 V) 5.0 V (0.25 V) 5.0 V (0.25 V) 5.0 V (0.25 V) Reserved
1
Pin 14 15 16 17 18 19 20 21 22
4
Description GND GND GND GND RS-232 OUT (TTL) Loss of Input Power Alarm6 Reserved1 Amplifier Disable Input 7 RS-232 IN (TTL) Reserved1 5.0 V (0.25 V) GND --
Reserved1 EDFA Temperature Alarm Loss of Output Power Pumps Bias Alarm3 Pumps Temperature Alarm EDFA Shutdown Override 5.0 V (0.25 V) GND
5
Alarm2
23 24 25 --
Do not connect to reserved pins. Normal = TTL low, alarm = TTL high if the output power falls 2 dB below the minimum value. Normal = TTL low, alarm = TTL high if pump bias exceeds 95% of its end-of-life value. Normal = TTL low, alarm = TTL high if pump temperature exceeds 35 C. The EDFA is equipped with an optical transient suppression feature when this pin is tied to GND. The EDFA will turn all pumps off, if the input power is too low. Tying this pin to 5 V will disable this feature; however, damage to the optical connectors and components may occur if the amplifier is turned on without the presence of an optical signal. 6. Normal = TTL low, alarm = TTL high if input power is less than 2 dB below minimum PIN. 7. Amplifier enable (all pumps are on) = TTL low, amplifier disable (all pumps are off) = TTL high.
Agere Systems Inc.
3
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Data Sheet July 1999
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess of those given in the operational sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect device reliability. Parameter Storage Temperature Operating Case Temperature Absolute Humidity Symbol Tstg TC -- Min -40 0 -- Typ 20 35 -- Max 70 65 0.024 Unit C C lbs. H2O/lbs. dry air
Electrical Characteristics
Table 2. Power Supply Parameter dc Power Supply Voltage Power Supply Current (beginning of life): 19 dBm 22 dBm Power Supply Current (end of life): 19 dBm 22 dBm Electrical Power Consumption (beginning of life): 19 dBm 22 dBm Electrical Power Consumption (end of life): 19 dBm 22 dBm Symbol VPS1 Min 4.75 Typ* 5.0 Max 5.25 Unit V
IPS1 IPS1
-- --
1.0 2.4
-- --
A A
IPS1 IPS1
-- --
-- --
1.9 3.8
A A
-- --
-- --
5.0 12.0
-- --
W W
-- --
-- --
-- --
10.0 20.0
W W
* Typical operating characteristics: VPS1 = 5.0 V, TC = 35 C.
4
Agere Systems Inc.
Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Electrical Characteristics (continued)
Table 3. TTL Inputs/Outputs Under normal operating conditions, the various alarm outputs will be TTL level low. If the corresponding parameter is outside a predesignated range, the associated alarms will become TTL level high. Parameter Input Voltage: High Low Output Voltage: High Low Input Current: High Low Output Current: High Low Symbol VIH VIL VOH VOL IIH IIL IOH IOL Min 2 -- 2.4 0 -- -- -- -- Typ -- -- -- 0.1 -- -- -- -- Max -- 0.8 -- 0.4 -1 1 -4 20 Unit V V V V A A mA A
Agere Systems Inc.
5
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Data Sheet July 1999
Optical Characteristics
Table 4. Performance Specifications for S Series Parameter Signal Wavelength Range Measurement Wavelength Input Signal Power: Preamp--S1724A-Type Booster/In Line--S1724B/C/D-Types Gain (PIL = -30 dBm): Preamp--S1724A-Type Peak Output Power (TC = 35 C; over M): Booster/In Line--S1724B-Type --S1724C-Type --S1724D-Type Noise Figure: Preamp--S1724A-Type (PIL = -30 dBm; M) Booster/In Line--S1724B/C/D-Types (PIL = -6.0 dBm; M) Return Loss Output Power Stability (over temperature, at a constant input power) Table 5. Performance Specifications for V Series Parameter Signal Wavelength Range Measurement Wavelength Input Signal Power Peak Output Power (at M and TC = 35 C): V1724B-Type V1724C-Type V1724D-Type V1724E-Type Noise Figure (PIL = 0 dBm, M) Return Loss Composite Second Order Composite Third Beat Output Power Stability (over temperature and input power variations) Symbol L M PIL PO PO PO PO NF RL CSO CTB PO Min 1540 -- 0 13 16 19 22 -- -- -- -- -- Typ -- 1550 -- -- -- -- -- 4.75 -- <-70 <-70 0.2 Max 1560 -- 10 -- -- -- -- 5.5 -40 -- -- 0.5 Unit nm nm dBm dBm dBm dBm dBm dB dB dBc dBc dB Symbol L M PIL PIL G PO PO PO NF NF RL PO Min 1530 -- -30 -6.0 30 13 16 19 -- -- -- -- Typ -- 1550 -- -- -- -- -- -- -- -- -- 0.2 Max 1560 -- -- -- -- -- -- -- 5.0 5.5 -40 0.5 Unit nm nm dBm dBm dB dBm dBm dBm dB dB dB dB
6
Agere Systems Inc.
Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Outline Drawings
1724-Type EDFA Package*
Dimensions are in inches and (millimeters).
MOUNTING HOLES M3 x 0.5, 5 mm DEEP 4 PLACES
5.074 (128.88)
0.41 (10.4)
LABELS AS REQUIRED
4.660 (118.36) DANGER LABEL
HEATSINK MOUNTING HOLES M3 x 0.5, 4.5 mm DEEP 5 PLACES
5.90 (149.9)
0.12 (3.0)
4.90 (124.5) DB 25 CONNECTOR MALE PIN 1 2.285 (58.04) 4.57 (116.08) 3.10 (78.7)
ESD LABEL 0.165 (4.19) 0.44 (11.2) 5.570 (141.48) 0.90 (22.9) 0.76 (19.3) 0.17 (4.2)
3.795 (96.39)
0.83 (21.1) 0.03 (0.8)
INFORMATION LABEL
1-997(C)
* B version shown; see coding scheme in Table 6, Ordering Information.
Agere Systems Inc.
7
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Data Sheet July 1999
Outline Drawings (continued)
Optional Package Configuration: 1724-Type EDFA Package with Integral Heat Sink*
Dimensions are in inches and (millimeters).
CUSTOMER LABEL LASER WARNING LABEL
1.500 (38.10)
DANGER
0.033 (0.84) 5.90 (149.9) 0.41 (10.5) 5.074 (128.88)
0.44 (11.2)
DB 25 CONNECTOR (MALE)
4.660 (118.36)
4.91 1.850 (124.7) (46.99)
AGERE SYSTEMS Breinigsville, Pennsylvania USA DATE MANUFACTURED: NOVEMBER 1997
PIN 1
0.76 (19.3)
1.53 (38.9)
0.123 (3.12) 0.98 (24.8) 3.94 (100.1) MOUNTING HOLES M3 x 0.5, 5 mm DEEP AS NOTED BY DIMPLE 4 PLACES
0.38 (9.5)
* F version shown; see coding scheme in Table 6, Ordering Information.
1-998(C)
8
Agere Systems Inc.
Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Ordering Information
Table 6. Ordering Information* Device Code S1724BBBA S1724BDBA S1724CBBA S1724CDBA S1724DDBA V1724BBBA V1724BHBA V1724CBBA V1724CGDA V1724CHBA V1724DBBA V1724DHBA V1724EBBA V1724EHBA Po 13.0 dBm 13.0 dBm 16.0 dBm 16.0 dBm 19.0 dBm 13.0 dBm 13.0 dBm 16.0 dBm 16.0 dBm 16.0 dBm 19.0 dBm 19.0 dBm 22.0 dBm 22.0 dBm Connector SC/PC FC/PC SC/PC FC/PC FC/PC SC/PC SC/APC SC/PC FC/APC SC/APC SC/PC SC/APC SC/PC SC/APC Heat Sink No No No No No No No No Yes No No No No No Comcode 108321472 108313719 108331539 108313727 108319088 108331547 108468398 108331554 108363680 108468406 108331562 108351842 108331984 108351859
* Contact your Account Manager to discuss your requirements. (If you do not know your Account Manager, please call Agere Systems, Optoelectronics unit directly at (610) 391-2520.)
Coding Scheme
Example: 1724 = 1724 series indicator: S = single channel V = video = output power indicator: A < 12.99 dBm B S 13 dBm C S 16 dBm D S 19 dBm E S 22 dBm = optical connector indicator: B = SC/PC D = FC/PC G = FC/APC H = SC/APC = housing-type indicator: B = no heat sink; fibers opposite DB25 connector D = heat sink; fibers opposite DB25 connector F = heat sink; fibers 90 from DB25 connector = future use
Agere Systems Inc.
9
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Data Sheet July 1999
Related Product Information
Table 7. Related Product Information Description High-Speed Lightwave Receiver Lithium Niobate Modulator Electroabsorption Modulated Isolated Laser Module 1.5 m Isolated DFB Laser Module 1.3 m Isolated DFB Laser Module 0.98 m Pump Laser Module Long-Wavelength PIN Photodetectors Interfacing the 1724-Type Microprocessor-Controlled Erbium-Doped Fiber Amplifier via a Serial Communication Port Part Number 1319-Type -- E2500-Type D2500-Type D2300-Type 263-Type 131-Type 1724-Type EDFA Document Number DS97-106LWP DS98-110LWP DS98-368LWP DS98-339LWP DS97-122LWP DS99-199LWP DS98-206LWP AP99-020LWP
10
Agere Systems Inc.
Data Sheet July 1999
Optical Amplifier Platform, 1724-Type Erbium-Doped Fiber Amplifier (S and V Series)
Laser Safety Information
Class IIIb Laser Product
This product complies with 21 CFR 1040.10 and 1040.11. Single-mode connector Wavelength = 1.55 m Maximum power <500 mW Product is not shipped with power supply. CAUTION: Use of controls, adjustments, and procedures other than those specified herein may result in hazardous laser radiation exposure.
DANGER
INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM.
m
Indium Gallium Arsenide Phosphide Laser <500 mW max. Output @ 1.55 m Class IIIb Laser Product Complies with 21 CFR 1040.10 and 1040.11
DANGER INVISIBLE RADIATION IS EMITTED FROM THE END OF THE FIBER OR CONNECTOR. AVOID DIRECT EXPOSURE TO THE BEAM. DO NOT VIEW WITH OPTICAL INSTRUMENTS.
Agere Systems Inc.
11
For additional information, contact your Agere Systems Account Manager or the following: INTERNET: http://www.agere.com E-MAIL: docmaster@agere.com N. AMERICA: Agere Systems Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286 1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106) ASIA: Agere Systems Hong Kong Ltd., Suites 3201 & 3210-12, 32/F, Tower 2, The Gateway, Harbour City, Kowloon Tel. (852) 3129-2000, FAX (852) 3129-2020 CHINA: (86) 21-5047-1212 (Shanghai), (86) 10-6522-5566 (Beijing), (86) 755-695-7224 (Shenzhen) JAPAN: (81) 3-5421-1600 (Tokyo), KOREA: (82) 2-767-1850 (Seoul), SINGAPORE: (65) 778-8833, TAIWAN: (886) 2-2725-5858 (Taipei) EUROPE: Tel. (44) 7000 624624, FAX (44) 1344 488 045
Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application.
Copyright (c) 2001 Agere Systems Inc. All Rights Reserved
July 1999 DS99-259LWP (Replaces DS98-412LWP)


▲Up To Search▲   

 
Price & Availability of S1724BBBA

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X